Slave Pumps
Caution: Always wear proper safety equipment (glasses, gloves, respirator, etc.) when working on spray equipment.
-
Problem Catalyst spitting from gun. Intermittent catalyst flow.
-
Possible Causes: Air is drawn into catalyst siphon assembly.Solution: Replace inlet nipple.
-
Possible Causes: Cracked or deteriorated (pin holes) inlet nipple at bottom of slave
pump.Solution: Replace inlet nipple. -
Possible Causes: Worn or cut o-ring in inlet nipple.Solution: Replace o-ring in inlet nipple.
-
Possible Causes: Improper seal around siphon hose.Solution: Check seal and be sure hose is inserted all the way into nipple.
-
Possible Causes: Cracked or deteriorated (pin holes) catalyst siphon hose.Solution: Replace catalyst siphon hose.
-
Possible Causes: Cracked or deteriorated elbow assembly on catalyst jug
assembly.Solution: Replace elbow assembly. -
Possible Causes: Air trapped in system.Solution: Reprime line by hand.
-
-
Problem No catalyst coming from gun.
-
Possible Causes: Ball valve open on catalyst manifold (if applicable).Solution: Be sure ball valve is fully closed.
-
-
Problem No catalyst flow on down stroke of catalyst pump.
-
Possible Causes: Debris in lower ball and seat assembly.Solution: Remove and clean.
-
Possible Causes: Chipped or worn ball and/or seat.Solution: Inspect and replace ball and/or seat if necessary.
-
-
Problem No catalyst flow on upstroke of catalyst pump.
-
Possible Causes: Debris in ball seat assembly located at bottom of pump shaft
(commonly referred to as upper bal seat assembly).Solution: Remove and clean. -
Possible Causes: Chipped or worn ball and/or seat assembly.Solution: Inspect and replace ball and/or seat if necessary.
-
-
Problem Loss of catalyst pressure.
-
Possible Causes: Worn or cut o-ring on ball seat assembly located on bottom of
pump shaft (commonly referred to as upper ball seat assembly).Solution: Replace o-ring. -
Possible Causes: Sticking catalyst pressure relief valve assembly, located on
catalyst manifold (if applicable).Solution: Disassemble, inspect and clean.
Replace seals if necessary.
-
-
Problem Catalyst leaking from top of catalyst slave pump.
-
Possible Causes: Worn or cut o-rings located in top of pump.Solution: Replace o-rings.
-
Possible Causes: Upper packings need to be adjusted (if applicable).Solution: Adjust packing nut 1/8 to 1/4 turn, with pump depressurized.
-
Possible Causes: Bent catalyst pump shaft.Solution: Replace pump shaft.
-