Manual Head Megaject MkV
Megaject MkV Polyester
5cc Stainless Steel slave pump – Part Ref: 5818
Suitable for mixing and injecting Polyester, Vinylester and Methacrylate resin systems. The catalyst ratio can be infinitely adjusted from
0.5% to 3.5%.
Megaject MkV Epoxy
Part Refs: 2:1 Catalyst Pump Ratio – 5819 OR 1:1 Catalyst Pump Ratio – 5820
Suitable for mixing and injecting Epoxy resin systems. The Hardener ratio can be infinitely adjusted from 8% to 100% when using either:
50cc secondary Hardener pump (2:1) 8% - 50% 100cc pump (1:1) 20% - 100%
Megaject MkV Phenolic
20cc Stainless Steel slave pump – Part Ref: 5821
Suitable for mixing and injecting Phenolic resin systems. - The catalyst ratio can be infinitely adjusted from 3% to 20%.
Related Files:
- Description
Machine specification for manual head polyester, epoxy and phenolic:
- Complete 2 stream mixing head with standard static mixer element, air/solvent/air cleaning system and head start button.
- 4m umbilical to head with industrial tough flexible chemically resistant protection.
- Manual Resin and Catalyst re-circulation at head with manual valve interlocks.
- Heavy-duty ratio arms with precision roller bearing fulcrums.
- Ratios manually adjusted using low friction lead screws.
- 100cc Primary Resin Pump with inlet hose and filter suitable for a 200kg drum.
- Full instrumentation and control panel, housed in steel lockable cabinet.
- MPG, Mould Pressure Guard.
- RGA, Resin Gel Alarm provides intelligent visual and audible alarm conditions during and after machine injection.
- Timed solvent flush of machine head (cancels RGA).
- Air purge and head dry out control.
- Pre-determining stroke counter (count rate every 100cc). When the predetermined count is reached the machine is stopped automatically.
- Frame mounted 20lt heavy-duty polypropylene non-pressurised solvent tank with submersed solvent pump system, SP-3.
- Highly efficient solvent/air emulsifier ensuring lower solvent consumption per head flush.
- On board mould vacuum facility.
- Emergency stop, air failure machine shutdown with safe automatic restart on reset.
- Machine guards complying with CE Machinery Directive regulations.
- Catalyst over-pressurisation, auto machine stop.
- The machine comes with comprehensive commissioning and installation instructions and signed factory test and calibration sheets, where applicable. Designed to connect to and control: TURBO AUTOSPRUE - Automatic injection valve. PVSENSOR – For precise mould pressure control